※ 用途 Usage:
 
  ◆ 用于金属元器件除气、烧结。
  ›  Used for metal components degassing, sintering.

※ 设备特点 Features:

  ◆ 工业级触摸屏平板电脑,和PLC之间采用可靠的现场总线方式连接,保证系统运行可靠性;配备多串口卡,通过RS232或RS485方式与各种控制器连接;
  ›  Industrial touch screen Tablet PC and PLC are connected by reliable field bus connection, to ensure system operation reliability; equipped with multi serial card, through the RS232 or RS485 mode and all kinds of controller connection;
  ◆ 以通用组态软件---组态王6.52作开发平台开发而成,系统温度参数以及温度曲线可灵活设置、存贮、调用,能保持不少于5条工艺参数,与不少于5组PID参数,调用工艺参数到温控表时,同时也将相应的PID参数下载在仪表中,不需要再手动速整定,具有实时曲线、较为完善历史曲线及历史数据记录与查询等功能;
  ◆ 界面友好,工艺参数设置和修改操作简单,过程显示清楚(已执行、正在执行和未执行的过程可在视觉上明显区分);
  ◆ 参数设置完成后可实现真空→加热→放气的一键式全过程自动化;
  ◆ 极限真空:2×10-4Pa(真空腔内为洁净、无负载、环境温度为27℃以下测定);
  ◆ 复真空:大气至5×10 -3Pa≤20min;
  ◆ 加热温度:最高1200℃,使用温度600-1150℃,有效温区Φ300X150mm,温度可控可调,控温精度±2℃,可设置升降温曲线;
  ◆ 真空室:翻盖阱式,不锈钢材料,外壁通冷却水;尺寸约Φ500mmXΦ400mm,箱体内表面抛光处理,外表面化学处理;
  ›  The system temperature parameter and the temperature curve can be set, stored and called, can keep no less than 5 process parameters, and not less than 5 Group PID parameters, call the process parameters to the temperature control table, but also the corresponding PID parameters downloaded in the instrument, do not need to manually set the speed, with real-time curve, more perfect history curve and historical data records and inquiries and other functions;
  ›  The interface is user friendly, the process parameters are set and the operation is simple, the process is clearly visible (The process of execution, execution and execution is visually distinctly distinguishable);
  ›  After the completion of the parameters set to achieve the vacuum state→ heating → deflated one-click the whole process of automation;
  ›  Limit vacuum: 2 × 10-4Pa (Vacuum chamber is clean, no load, the ambient temperature below 27 ℃);;
  ›  Restore the vacuum: the atmosphere to 5 × 10 -3Pa ≤ 20min;
  ›  Heating temperature: up to 1200 ℃, the usage of temperature 600-1150 ℃, the effective temperature range Φ300X150mm, adjustable temperature control, temperature control accuracy of ± 2℃, can be set to rise and fall curve;
  ›  Vacuum chamber: flip cover type, stainless steel material, the outer wall of the cooling water; size about Φ500mmXΦ400mm, the inner surface of the box polished, the outer surface of chemical treatment